{"product_id":"hazard-meters","title":"MX Hazard Zone Meters - Macnaught Canada","description":"\u003ch2\u003e\u003cspan\u003eMacnaught Hazard Zone Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMacnaught MX ExD, Intrinsically Safe, and Simple Safe Flow Meters were designed, certified and approved for most fluid Hazard Zone Atmospheres.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMacnaught Hazard Meters are for clean process fluids and do not measure gases of fluids with solids. Clean Process Liquids only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MX Hazard Meter offering provides inline .5% Volumetric Accuracy with .03% Repeatability.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn Stock Sizes ¼” thru 4” .13 GPH to 320+ GPM\u003c\/li\u003e\n\u003cli\u003eNo Flow Conditioning - put the meter where you want it\u003c\/li\u003e\n\u003cli\u003eLarge in-stock inventory of Hazard Meters and Displays\u003c\/li\u003e\n\u003cli\u003eQuick response to Hazard Meter inquiries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReceive an Immediate Flow Meter Proposal or Call our \u003cspan style=\"color: #ff2a00;\"\u003eMeter Hotline - \u003ca href=\"tel:6474278771\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e(647) 427-8771\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/macnaught.ca\/pages\/request-for-quote\" class=\"button button--red\" title=\"Request a Quote\" target=\"_blank\"\u003eMETER RFQ FORM\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cu\u003eNFPA 70 NEC Location Classes, Divisions, and Groups\u003c\/u\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClass I definition:\u003c\/strong\u003e Flammable gases or vapors may be present\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiv 1 definition:\u003c\/strong\u003e Ignitable concentrations of hazards exist under normal operation and\/or where the hazard Is caused by frequent maintenance or repair work or frequent equipment failure\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiv 2 definition:\u003c\/strong\u003e Ignitable concentrations of hazards exist under abnormal operation conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGroup A:\u003c\/strong\u003e Acetylene\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGroup B:\u003c\/strong\u003e Hydrogen, Butadiene, Ethylene, Oxide, Propylene Oxide, and Acrolein\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGroup C:\u003c\/strong\u003e Ethylene, Cyclopropane, Ethyl Ether\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGroup D:\u003c\/strong\u003e Acetone, Ammonia, Benzene, Butane, Ethanol, Gasoline, Hexane, Methane, Methanol, Naphtha, Natural Gas, Propane, and Toluene\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eHazard Zone \/ Class FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a piece of equipment approved for use in a Division 1 hazardous location in a Division 2 hazardous location?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.\u003cbr\u003e\u003cstrong\u003eQ: Can equipment approved for a Class I hazardous location be used in a Class II hazardous location?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Equipment approved for use in Class I hazardous locations cannot be used in Class II hazardous locations.\u003cbr\u003e\u003cstrong\u003eQ: Are Divisions and Zones equivalent to one another?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e When comparing Divisions and Zones, Division 2 is equivalent to Zone 2, but Division 1 is equivalent to either Zone 0 or 1\u003c\/p\u003e\n\u003cp\u003eContact Macnaught Canada for approved Hazard Zone Liquid Flow Meters – the leading global manufacturer of specialized Oval Gear \u0026amp; Turbine Flow Measurement Devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReceive an Immediate Flow Meter Proposal or Call our Meter Hotline - \u003ca href=\"tel:6474278771\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e(647) 427-8771\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/macnaught.ca\/pages\/request-for-quote\" class=\"button button--red\" title=\"Request a Quote\" target=\"_blank\"\u003eMETER RFQ FORM\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eExD Specs\u003c\/h5\u003e\n\u003ch2\u003e\u003cstrong\u003eExD Quick Specs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMacnaught ExD Flow Meters and Displays meet all ExD (Flameproof) CID1 approvals and certifications. FM-US and FM-CA, ATEX and IECEx approved and certified.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eMacnaught MX ExD Quick Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"fusion-clearfix\"\u003e\n\u003ctable style=\"width: 650px;\" height=\"336\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e\n\u003cstrong\u003eSize Connection\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e\n\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e\n\u003cstrong\u003eMax\u003cbr\u003eTemp\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBody\u003cbr\u003eRotor MOC\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX06 \u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e¼”\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e.13-26 GPH\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e1,000 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX09\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e¼”\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e4-132 GPH \u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e1,000 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX12\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e½”\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e.5-8 GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e2,000 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX19\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e¾”\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e.8-21 GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e2,000 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ PEEK-SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX25\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e1”\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e1.6-32 GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e2,000 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ PEEK-SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX40\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e1.5\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e2.6-66 GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e1,500 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ PEEK-SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX50\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e2\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e4-200 GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e1,200 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eSS-AL \/ PEEK-SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX75 \u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e3”\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e5-194 GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e175 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eAL \/ AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 63px; height: 19px; text-align: center;\"\u003eMX100\u003c\/td\u003e\n\u003ctd style=\"width: 75px; height: 19px; text-align: center;\"\u003e4\"\u003c\/td\u003e\n\u003ctd style=\"width: 93px; height: 19px; text-align: center;\"\u003e31-320+ GPM\u003c\/td\u003e\n\u003ctd style=\"width: 112px; height: 19px; text-align: center;\"\u003e175 PSI\u003c\/td\u003e\n\u003ctd style=\"width: 73.2344px; height: 19px; text-align: center;\"\u003e284F\u003c\/td\u003e\n\u003ctd style=\"width: 128.766px; height: 19px; text-align: center;\"\u003eAL \/ AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFM-US and FM-CA Certification Markings:\u003c\/strong\u003e \u003cbr\u003eUSA \u0026amp; CAN: Class 1 Division 1 GROUP ABCD T6...T3 Class 1, Zone 1, AEx\/Ex db IIC T6...T3 Gb T3 @ Ta = -50°C… +140°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eATEX and IECEx:\u003c\/strong\u003e\u003cbr\u003eATEX \u0026amp; IECEx: II 2 G Ex db IIC T6...T3 Gb, T3@ Ta = -55°C… +140°C\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eMacnaught ExD Downloads\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMX Hazard Manual\u003c\/strong\u003e \u0026gt; \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0856\/3762\/8177\/files\/MXEX_INST-R15-0_6180e5c9-ff33-45d4-a44b-e7f96b298d38.pdf?v=1787058918\" title=\"Manual\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eDownload PDF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE110 C1D1 Display Datasheet\u003c\/strong\u003e \u0026gt; \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0856\/3762\/8177\/files\/E110_7be68a97-f6c4-4d20-b0f2-3efc682349c1.pdf?v=1787058917\" title=\"Data Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eDownload PDF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring ExD Meter to E110 Display\u003c\/strong\u003e \u0026gt; \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0856\/3762\/8177\/files\/E110-ExD-Display-DataSheet_f4a43a86-780d-4408-adab-83c5a8e0c6e0.pdf?v=1787058916\" title=\"Data Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eDownload PDF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePD6830 C1D1 Display Datasheet\u003c\/strong\u003e \u0026gt; \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0856\/3762\/8177\/files\/6830-Exd-PreDig_1ed99136-9f42-4c0e-a68b-ef0116e02602.pdf?v=1787059058\" title=\"Data Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eDownload PDF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring ExD Meter to PD6830\u003c\/strong\u003e\u0026gt; \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0856\/3762\/8177\/files\/Type-A-Pulse-Hall-Output-to-PD6830_ef17cf57-3f6e-4cc1-bc14-0fda9c0cc8c7.pdf?v=1787059057\" title=\"Data Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003eDownload PDF\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNotes:\u003c\/strong\u003e \u003cbr\u003eMX ExD Sensor Type is NPN\u003cbr\u003eOperating Voltage: 5VDC-27VDC @ \u0026lt; 15mA\u003cbr\u003eStandard Cable Length: 3 Meters\u003cbr\u003eMinimum Temp: -58F\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLarge ExD Meter and Display Inventory in Tampa FL Stock\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCall our\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eMeter Hotline\u003c\/span\u003e \u003c\/strong\u003e\u003ca href=\"tel:6474278771\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e(647) 427-8771\u003c\/a\u003e or use the\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Request a Quote\" href=\"https:\/\/macnaught.ca\/pages\/request-for-quote\"\u003e\u003cstrong\u003eRFQ Form Link Below\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/macnaught.ca\/pages\/request-for-quote\" class=\"button button--red\" title=\"Request a Quote\" target=\"_blank\"\u003eMETER RFQ FORM\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Declaration of Conformity (Simple Apparatus PCB)\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0630\/5175\/9801\/files\/MXEX-IS-INST_R1_1_480x480.jpg?v=1668524081\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eMacnaught Canada can review your Hazard application and determine best fit. Contact our \u003cspan style=\"color: #ff2a00;\"\u003eMeter Hotline \u003c\/span\u003eat \u003ca href=\"tel:6474278771\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e(647) 427-8771\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOr Complete our Meter RFQ form for an immediate proposal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/macnaught.ca\/pages\/request-for-quote\" class=\"button button--red\" title=\"Request a Quote\" target=\"_blank\"\u003eMETER RFQ FORM\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"fusion-clearfix\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"fusion-clearfix\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch5\u003eExD Video Overview\u003c\/h5\u003e\n\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/uluYX6LD00E?si=zbW7PddLRtK-rxEy\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e","brand":"Macnaught","offers":[{"title":"Default Title","offer_id":54279131758865,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0856\/3762\/8177\/files\/ExD-explosion-flame-proof_a86fd192-67e9-4c7e-a91a-32ee73231ec0.jpg?v=1787057167","url":"https:\/\/macnaught.ca\/products\/hazard-meters","provider":"Macnaught Canada","version":"1.0","type":"link"}